BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography

    Buy cheap BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography from wholesalers
     
    Buy cheap BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography from wholesalers
    • Buy cheap BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography from wholesalers
    • Buy cheap BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography from wholesalers

    BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography

    Ask Lasest Price
    Brand Name : ZOSBIO
    Model Number : 2019-NCoV Neutralizing Antibody
    Certification : CE BfArm
    Price : To be negotiated
    Supply Ability : 10000 Kit/Kit per Day
    Delivery Time : To be negotiated
    • Product Details
    • Company Profile

    BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography

    2019-NCoV Neutralizing Antibody Rapid Test (Immunochromatography)


    Intended Use


    The kit is used for the qualitative detection of 2019-nCoV neutralizing Ab in human serum,plasma, and whole blood samples.
    As a new type, 2019-nCOV is a kind of β-COVs. It can cause viral pneumonia, with main clinical manifestations of fever, fatigue and dry cough. A few patients are accompanied by nasal congestion, runny nose, sore throat, diarrhea and other symptoms. Critical cases often develop
    dyspnea and/or hypoxemia after a week, and those at serious condition rapidly progress to acute respiratory distress syndrome, septic shock, difficult-to-correct metabolic acidosis, and coagulation dysfunction

    Principle of Detection



    The kit uses immunochromatography. The test card contains quality control line C, test line T and reference line R. The sample to be tested (serum/ plasma/ whole blood) diffuses upwards by capillary action at the loading well, and S-RBD of the maker in the binding pad binds to the immobilized ACE2 protein on the NC membrane, and the signal can be detected at the position of T line. If there is neutralizing antibody in the sample, it will bind to the labeled S-RBD antigen when flowing through the labeling pad. The neutralizing antibody can prevent the binding of S-RBD toACE2,resulting in a decrease in the signal value, and the T-line signal value is negatively correlated with the neutralizing antibody content, and when the neutralizing antibody concentration is high enough, there is no color on the T-line. The reference line R and quality control line C should be colored regardless of whether T line is colored or not. Quality control line C is used foruality control. If there is no color display on C line, the test is invalid and the sample must bere-tested

    Main Components


    The kit consists of a test card and sample buffer

    Test card: It is composed of aluminum foil bag, desiccant, test strip and plastic card. Among them, the test strip is composed of absorbent paper, nitrocellulose membrane, sample pad,binding pad and rubber sheet. The nitrocellulose membrane T line (test line) is coated

    with ACE2 protein, the C line (quality control line) is coated with Ab on quality control line, the R line (reference line) is coated with reference Ab, and the binding pad contains marker-labeled 2019-nCoV Ab.
    Sample buffer: Phosphate, sodium azide, etc.

    Storage Conditions and Validity


    Keep it at 2℃ ~ 30℃, and the validity period is set at 12 months.
    The validity period is an hour for aluminum foil bag being unpacked.
    Batch No. : See label for details.
    Expiration date: See label for details

    Sample Requirements



    1.Collect serum, plasma or whole blood samples.

    2.The sediment and suspended matter in the sample may affect the experimental results, andshould be removed by centrifugation.

    3. Anticoagulant: Heparin, EDTA and sodium citrate anticoagulant have no significant effect.

    4. Blood collection should be performed by professional medical personnel. It is recommended to give priority to serum/plasma test. In emergency or special circumstances, the patient's whole blood sample can also be used for rapid test.

    5. Serum and plasma samples should not be stored at room temperature for more than 8h. They can be stored for 5 days at 2℃ to 8℃ and for 6 months below -20℃, but repeated freeze-thaw cycles should be avoided. Whole blood samples should not be frozen and it should be stored at 2℃~8℃ for no more than 48h


    Test Method


    Read the instructions carefully before testing. Please return all reagents to room temperature before testing, and the test should be performed at room temperature.

    1.Take out the test card from the packaged reagent bag and use it within an hour.

    2.Add 20μL of sample (serum, plasma or whole blood) to the loading well of the test card, then add 2 drops (about 60μL) of sample buffer and then start timing.

    3. Read the result when reacting at room temperature for 10-15 minutes. The result is invalid after 20 minutes


    Interpretation of Test Results



    Interpretation of test card:

    1. Invalid result: It is invalid with no reaction line on the quality control line (C line), and the test should be carried out again.
    2. Negative result: A red band appears on the test line (T line), and the color rendering is higher than or equal to the reference line (R line), and the quality control line (C line) and reference line (R line) are colored.
    3. Positive result: No red band appears on the test line (T line), or the red band on the test line (T line) is less coloring than the reference line (R line), and the quality control line (C line) and the reference line (R Line) are colored.

    Limitation of Test Method



    1. This kit is for qualitative detection and is only used for in vitro auxiliary diagnosis.
    2. Make sure to add an appropriate amount of sample for test. Too much or too little sample volume may result in inaccurate results.
    3. Hemolysis, lipemia, jaundice and contaminated samples may affect the test results, and these samples should be avoided.
    4. The test results of this reagent are for clinical reference only, and should not be used as the sole basis for clinical diagnosis and treatment. The final diagnosis of the disease should be made after a comprehensive evaluation of all clinical and laboratory results.

    Product Performance Indicators


    1.Analysis of specificity

    1.1Cross reaction: The following types of antibodies were evaluated for interference with reagents, and the results showed no cross-reaction.


    SNItemCross reactionSNItemCross reaction
    1Endemic human coronavirus OC43No10EnterovirusNo
    2Endemic human coronavirus HKUINo11EB virusNo
    3Endemic human coronavirus NL63No12Measles virusNo
    4Endemic human coronavirus 229ENo13Human cytomegalovirusNo

    5Influenza A virusNo14RotavirusNo
    6Influenza B virusNo15NorovirusNo
    7Respiratory syncytial virusNo16Mumps virusNo
    8AdenovirusNo17Varicella-zoster virusNo
    9RhinovirusNo18Mycoplasma pneumoniaeNo

    1.2Interfering substances: The following concentrations of substances were added to the samples at the specified concentrations to evaluate their potential interference in 2019-nCoV neutralization Ab test project. The results showed that all kinds of interfering substances did not interfere with the test results of this reagent.


    Interfering substancesConcentrationInterfering substancesConcentration
    Bilirubin≤50mg/dLTriglycerides≤15mmol/mL
    Hemoglobin≤5g/LCholesterol L≤500mg/d
    Rheumatoid factor≤500IU/mLHuman total IgG≤14mg/mL
    Ribavirin0.4mg/mLFluticasone0.5mg/mL
    Oxymetazoline10mg/mLDexamethasone5 mg/mL
    Histamine hydrochloride10mg/mLTriamcinolone acetonide5mg /mL
    Tobramycin1mg/mLLevofloxacin0.2 mg/mL
    Oseltamivir1mg/mLAzithromycin0.1 mg/mL
    Zanamivir1mg/mLCeftriaxone0.4 mg/mL
    Arbidol0.5mg/mLMeropenem0.2 mg/mL

    2.Clinical study: Using the marketed 2019-nCoV IgG Ab detection reagent (colloidal gold method) as a comparison reagent, 120 positive samples and 300 negative samples were selected for testing. The results are summarized as follows:


    2019-nCoV IgG Ab detection reagent (colloidal gold

    method)


    Sum

    PositiveNegative

    Positive1155120
    Negtive5295300
    Sum120300420
    Sensitivity95.83%, (95%CI: 90.62%~98.21%)
    Specificity98.33%, (95%CI: 96.16%~99.29%)

    Precautions


    1. This product is only used for in vitro diagnosis.
    2. This product is disposable, which cannot be recycled and reused.
    3. Read the instructions carefully before operation, and carry out the experimental operation in strict accordance with the reagent instructions.
    4. Avoid conducting experiments in bad environmental conditions (the environments containing 84 disinfectant, sodium hypochlorite, high-concentration corrosive gases such as acid and alkali or acetaldehyde, and dust). Laboratory disinfection should be carried out after the experiment.
    5. All samples and used reagents should be regarded as potentially infectious substances and disposed of in accordance with local regulations.
    6. Reagents should be used within the validity period marked on the outer package. The test card should be used as soon as possible after being taken out of the aluminum foil bag to prevent moisture.

    Logo interpretation




    Do not re-use

    Store at 2℃~30℃

    Consult instructions for use

    In vitro diagnostic medical

    device

    Batch code

    Use-by date
    Keep dry

    Keep away from sunlight

    Authorized representative in the

    European Community

    Manufacturer

    Basic Information


    ZHONGXIU SCIENCE AND TECHNOLOGY CO.,LTD

    Dingluan industrial zone ,Changyuan City,453400,P.R.CHINA Tel:+86-371-55016575

    Email:zosbio@zosbio.com

    Web:www.zosbio.com

    SUNGO Europe B.V.

    Olympisch Stadion 24, 1076DE Amsterdam, Netherlands


    Company profile


    Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
    The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

    Quality BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Henan Lantian Medical Supplies Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)